Direct Teach-In Of The Switching Channels - Balluff BIP LD2-T017-04-BP Serie Manual De Instrucciones

Ocultar thumbs Ver también para BIP LD2-T017-04-BP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 85
BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.9

Direct teach-in of the switching channels

The distance values for switching threshold programming
can be directly entered in the respective tabs and are then
saved permanently.
Channel
Index
Hex.
Dec.
BDC1
003C
60
003D
61
BDC2
003E
62
003F
63
BDC3
4000
16384
4001
16385
Tab. 6-10: Parameters for direct teach-in
14
english
Subindex
Access
Hex.
Dec.
01
1
Read/Write
02
2
01
1
Read/Write
02
2
03
3
01
1
Read/Write
02
2
01
1
Read/Write
02
2
03
3
01
1
Read/Write
02
2
01
1
Read/Write
02
2
03
3
Parameters
Setting / reading setPoint1
Setting / reading setPoint2
Setting / reading switch point logic
Setting / reading switch point mode
Setting / reading switch point hysteresis
Setting / reading setPoint1
Setting / reading setPoint2
Setting / reading switch point logic
Setting / reading switch point mode
Setting / reading switch point hysteresis
Setting / reading setPoint1
Setting / reading setPoint2
Setting / reading switch point logic
Setting / reading switch point mode
Setting / reading switch point hysteresis