Hall sensor evaluation / signal paths
Extended direction
Channel
A
B
•
External pull-up resistor required (normally 10 kW)
•
Hall sensor supply voltage range 5V ... 24 V
•
Current consumption: 5 mA quiescent current per sensor
•
Maximum hall sensor output current: 100 mA
Hall sensor resolving power
Tractor-design
per motor revolution
1000 N
2000 N
3000 N
With an edge evaluation, the accuracy
of the evaluation is doubled.
This principle is used for the RK synchronous controller
Connection to a RK transformer controller or an external
fixed source of voltage. With DIN loudspeaker connector
and connection cable guided out. Limit switch wired
internally.
Option
1
+
2
-
Number of pulses
2
2
2
Direction
-
Extend
+
Retract
Retracted direction
Channel
+DC
A
GND
+DC
B
GND
Gear X:1
Spindle pitch
16.5
16.5
16.5
Wiring diagram
7. Life phases
Accuracy/mm
8
+/- 0.24
6
+/- 0.18
4
+/- 0.12
Upper limit switch
M
Lower limit switch
63