Error Code Tests, cont'd.
Be sure you have followed the "Diag-
NOTICE
nostic Pre-Checks" before continuing.
Once the problem is corrected, you
MUST power the refrigerator off and
on to clear the fault code display.
Is unit production
date prior to Jan. 4,
Be sure you have followed the "Diag
NOTICE
nostic Pre-Checks" before continuing.
Once the problem is corrected, you
MUST power the refrigerator off and
on to clear the fault code display.
START
Is there fuel in the propane tank?
Yes
Is there an audible click or visual
spark at the gas valve?
Yes
Does the gap between the electrode
and burner measure approximately
3/16"?
Yes
Is electrode or electrode connection
damaged?
No
Does the burner orifice look clean; is
the flame dense and blue?
Yes
Check gas pressure. Does the WC
measure 11<12"?
No
Repair gas supply.
N3104, N3141, N3150 Models
START
Yes
2013?
No
Replace power
control board.
No
Turn unit off and on.
Is there a spark at the gas valve?
No
No
No
Adjust the electrode gap to 3/16"
Problem solved?
No
Yes
Repair electrode connection.
Problem solved?
No
No
Clean burner and orifice. If
necessary, replace burner.
Yes
Replace power control
board and LCD display.
Replace power
control board and
LCD display.
Replenish gas supply.
Is gas valve open during ignition
spark?
Yes
Replace gas valve.
Is unit production date prior to
Jan. 4, 2013?
Yes
Replace power control
10

Error Code 2

Burner control
module senses
incorrect
feedback
Yes
No
Error Code 3

Gas lockout

No
board.