INDICATOR
LED in the sensor flashes when user steps within the sensor range
CAUSE
Connectors between the electronic unit and the solenoid valve are disconnected
SOLUTION
Connect the connectors of the electronic unit to the solenoid valve
INDICATOR
LED in the sensor flashes when user steps within the sensor range
CAUSE
Debris or scale in solenoid
SOLUTION
Unscrew solenoid, pull out the plunger and the spring from solenoid. Clean them with pressure or use
scale remover material if needed
INDICATOR
LED in the sensor flashes when user steps within the sensor range
CAUSE
The central orifice in the diaphragm is clogged or the diaphragm is torn
SOLUTION
Clean the orifice or replace diaphragm