Models And Product Description; Description; Typical Installation; Installation - Comunello Automation LIMIT 500 Instrucciones De Uso

Ocultar thumbs Ver también para LIMIT 500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
2 MODELS AND PRODUCTS DESCRIPTION

2.1 DESCRIPTION

Sturdy and easy to install, the LIMIT electromechanical barrier system is
suitable for residential, public and industrial applications. Thanks to the on-
board electronic control unit any type of barrier system function can be
programmed.

2.2 TYPICAL INSTALLATION

D
E
B
KEY
A BARRIER SYSTEM WITH INTERNAL CONTROL UNIT
B PHOTOCELLS
C FLASHING LIGHT
D KEY SELECTOR SWITCH
E END REST
3 TECHNICAL SPECIFICATIONS
LIMIT 500
Operator power supply
Power consumption
Current input
Torque
300 Nm
Duty cycle
Protection rating
Insulation class
Working temperature
Weight
65 Kg

4 INSTALLATION

4.1 PRELIMINARY CHECKS

For correct operation of the automation system, make sure:
• all the accessories are suitably sized and properly maintained.
• all the operating limits of the product can be complied with.
• the minimum and maximum clearances shown in FIG. 1A, FIG. 1B
and are complied with.
• all material used is in perfect condition and fit for purpose.
• the selected installation site is compatible with the overall dimensions
of the product.
• there are no hindrances that could obstruct the opening and closing
movements of the barrier arm.
• the footing of the barrier system is able to provide stable anchorage
of the unit.
• the space around the barrier system is sufficient to allow easy and
safe execution of manual barrier operations.
• all devices to be installed are in a protected location so as to minimize
the risk of accidental impact.
• If necessary, create a pedestrian entrance well clear of the operating
range of the barrier arm.
4.2 APPLICATION LIMITS
Before installing the barrier gate check that its specifications are within the
operating limits shown in the chapter "Product Technical Specifications".
• Use an end rest for arms more than 3 m long.
• Leave a minimun distance of 50 centimeters between the LIMIT
and the curtain or between each curtain. In any case, the overall
C
A
B
LIMIT 600
24 V
150 W max
6,5 A
300 Nm
Intensive (15" ON - 45" OFF)
IP 24 D
II (2)
from -20°C to + 50°C
65 Kg
dimension of the curtain cannot exceed 5 m.

4.3 PREPARATORY WORK FOR INSTALLATION

• Embed counterplate and anchor bolts in concrete. Make sure to leave
out about 30mm of the anchor bolts (FIG. 2A / FIG. 2B).
• Embed counterplate and anchor bolts in concrete (FIG. 3A).
• If there is an existing concrete layer, drill it using the special template and
then embed the dowels (FIG. 3B)

4.4 INSTALLING THE LIMIT BARRIER SYSTEM

4.4.1
INSTALLATION:
• Remove the front cover using the supplied key (FIG. 4).
• Place the barrier raising system, sliding the power cords and
accessories through the central hole and anchor it with the nuts and
washers provided (FIG. 5A / 5B).
Arm assembly:
• Where required, attach the adhesive LED strip in the channel over the
full length of the arm (FIG. 6).
• If you wish to install the arm without impact protection strip, insert the
plug directly to its end (FIG. 7).
• If you wish to install the arm with the impact protection strip, place the
cover terminals at 220 mm from the bottom and then drill (FIG. 8A).
• Screw the cover terminals on both arm sides (FIG. 8B).
• Slide the impact protection strip along its guides, until it touches the
cover terminals (FIG. 8C).
Installing the arm:
• Release the operator as described in heading 4.4.3.
• Fix the arm support to the protruding pivot at the rear of the frame (FIG.
9A). Ensure it is in the "arm horizontal" position and that the internal
mechanism is in the position shown in FIG. 9B.
• Insert the arm inside the support together with the LED strip cable (if
provided for the model). Pull the cable from the rear of the support and
slide it through the hole below the pin. Then close the cover with the
screws (FIG. 9C).
• When the guides protrude by 100 mm, push them until they are flush
with the arm and fix the plug at the end (FIG. 10).
Fitting the spring:
Depending on the accessories and on the length of the arm, the spring can
be installed in the hole 1 or hole 2 or hole 3 of the spring stretcher tool. For
a correct installation please refer to the following table:
LIMIT 500 SPRING STRETCHER TOOL
1
3
1
2
ARM
ARM WITH IMPACT PROTECTION STRIPS AND LEDS
ARM WITH IMPACT PROTECTION STRIPS AND LEDS AND POGO
END REST
ARM WITH SINGLE IMPACT PROTECTION STRIP, LEDS AND SKIRT
ARM WITH SINGLE IMPACT PROTECTION STRIP, LEDS, SKIRT AND
POGO END REST
COMUNELLO ®Copyright 2017 - All rights reserved
ARM LENGTH (M)
2 m
3 m
4 m
5 m
3
2
1
1/2
1/2/3
1
1/2
2/3
1
1/2
3
-
2
3
-
3
3
2/3
3
3
-
-
29

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Limit 600

Tabla de contenido