Rain Bird STP-400i Manual De Instrucciones página 15

Ocultar thumbs Ver también para STP-400i:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Master Valve or Pump Start Relay
Step 3
To avoid possible pump damage
when using a Pump Start Relay,
connect a short jumper wire from
any unused zone terminal(s) to
the nearest zone terminal screw
in use.
EXAMPLE: if you have a 4 Zone
Controller with only two zones in
use, route the terminals for Zones
3 and 4 to the nearest active
terminal (in this example, Zone 2).
!
NOTE: Make sure that
the total draw of the
Master Valve or Pump
Start Relay, plus the
draw of the valves does
not exceed 0.650 Amps
at 24VAC, 60 Hz.
!
NOTE: This Controller
does not provide main
power for a pump.
637589-01 Rev 1 (STP user manual (INTL)) source.indd 13
Note these additional instructions when connecting a Pump Start Relay:
Active
Terminal
Jumper
Wires
STPi Controller Operation Manual
6/26/2008 2:19:06 PM
13

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Stp-600iStp-900i

Tabla de contenido