English
Overview of Functions
The electronics automatically recognizes an increasing filter pollution and re-adjusts the flowrate to the
value set by you. This guarantees constant flowrate values over a long period until a pollution degree is
reached which can no longer be compensated by the electronics.
Flowrate incrementally adjustable
(factory settings: 2074 = 585 l/h – 2076 = 650 l/h – 2078 = 700 l/h)
The electronically controlled alternating stream assures near-natural stream conditions in the aquarium.
Electronic alternation between two settable flowrates in a 12-hour rhythm.
Upon pushing the button, the device shows the remaining period to the next cleaning.
1 green LED = 1 month.
The system detects trapped air beneath the filter head and automatically bleeds the air off via an electronic
program.
The system constantly monitors itself, recognizes irregularities and indicates them in the form of warning
signals. At the same time, a program automatically attempts to rectify the respective causes.
electronic
error indicator
To guarantee maximum control accuracy, the system permanently checks and at least once a day calibrates
itself. For this procedure, the pump delivers a pre-set (high) flowrate and indicates this via a green se-
auto
quentially illuminated light.
calibration
The MANUAL MODE function is used to deactivate automatic readjustments and the service function.
manual
mode
The RESET FUNCTION is used to reset all the functions to the factory settings.
OPTIONAL: With the USB converter the EHEIM professionel 3
USB
puter via a USB interface. The functions can be conveniently controlled and monitored using the EHEIM
ControlCenter program. More detailed information is available at: www.eheim.de
connection
Technical Data
Pump max.
(1)
l/h
2074
1500
2076
1700
2078
1850
(1)
Max. pump capacity (without filter basket and connection accessories).
(2)
With recommended EHEIM filter media stacking and described hose installation.
(3)
(4)
= Factory settings
Min. filter capacity
e
Filter max.
(2)
EHEIM set
l/h
–
1000
1100
5
external filter can be connected to a com-
(3)
Filter min.
l/h
l/h
585
–
650
350
700
400
(4)