Dc Kit 2 With Dometic B2200; Dc Kit 3 With Dometic Ca1000 / Ca2500 - Waeco ECL-75 Instrucciones De Montaje

Ocultar thumbs Ver también para ECL-75:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63
_ECL-75_102.book Seite 36 Montag, 7. April 2008 11:31 11
Technical description
The air conditioner compressor is switched off in this way. The light system now charges
the starter battery. If the vehicle has a connecting cable between the two batteries, the
additional battery is also charged.
If the charging voltage of the light system UD+ reaches the set voltage value Ue again,
the power relay and the control relay switch on again. The air conditioner compressor
starts again.
If the vehicle engine is not switched on (UD+ = 0 V), relay contact 30/87 (Batt. I/Batt. II)
is opened and relay contact I2, I3 is closed. The air conditioner can be operated and only
takes power from the additional battery. If the battery voltage falls below Ubatt = 10.5 V,
the inverter switches off.
6.4

DC kit 2 with Dometic B2200

Circuit diagram, see page 6
Roof air conditioner: Dometic B2200
Charging current distributor: ECL-102
Inverter: ECW-012VS
The light system voltage UD+ is measured. If this voltage exceeds a variable voltage
value Ue (12.5 V - 14.0 V), the relay contact 30/87 (Batt. I/Batt. II) of the power relay is
closed. The starter battery and the additional battery are therefore connected in parallel
with low resistance and are charged together by the light system.
Contact I5/I2 is opened with UD+ > Ue and this switches the air conditioner on.
If the light system voltage falls below a variable threshold value Ua (10.5 V - 12.5 V), due
to an increased load because of the air conditioner, relay contact 30/87 (Batt. I/Batt. II) is
closed. Relay contact I5/I2, which interrupts the connection between the on/off cable and
the air conditioner, is opened.
The air conditioner is switched off in this way. The light system now charges the starter
battery. If the vehicle has a connecting cable between the two batteries, the additional
battery is also charged.
If the charging voltage of the light system UD+ reaches the set voltage value Ue again,
the power relay and the control relay switch on again. The air conditioner starts again.
If the vehicle engine is not switched on (UD+ = 0 V), relay contact 30/87 (Batt. I/Batt. II)
and relay contact I5/I2 are opened. The air conditioner can be operated and only takes
power from the additional battery. If the battery voltage falls below Ubatt = 10.5 V, the
inverter switches off.
6.5

DC kit 3 with Dometic CA1000 / CA2500

Circuit diagram, see page 7
Roof air conditioner: Dometic CA1000 / CA2500
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
36
ECL-75, ECL-102

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ecl-102

Tabla de contenido