Troubleshooting Test B - Not Cooling On Dc - Norcold N305 Manual De Servicio

Tabla de contenido

Publicidad

Troubleshooting, cont'd.

Troubleshooting Test B - Not cooling On DC

1. Perform the "Diagnostic Pre-Checks."
2. Remove unit from enclosure, leaving DC power connected. Have any wires become disconnected from their terminals?
■ Yes: Reattach wires and test unit; refer to the wiring diagram.
■ No: Go to the fl ow chart below.
Correct DC power
Correct DC power
to refrigerator
to refrigerator
No
No
Is there 12 volts DC at
Is there 12 volts DC at
terminal block
terminal block
(HC+ and HC- terminals)
(HC+ and HC- terminals)
Yes
Yes
Is there 12 volts DC at input of
Is there 12 volts DC at input of
fuse?
fuse?
20A fuse (N304M.3) Red wire
20A fuse (N304M.3) Red lead
25A fuse (N404M.3) Yellow wire
25A fuse (N404M.3) Yellow lead
25A fuse (N504M.3) Yellow wire
25A fuse (N504M.3) Yellow lead
Yes
Yes
Is there 12 volts DC at output of
Is there 12 volts DC at output of
fuse?
fuse?
20A fuse (N304M.3) Red lead
20A fuse (N304M.3) Red wire
25A fuse (N404M.3) Yellow wire
25A fuse (N404M.3) Yellow lead
25A fuse (N504M.3) Yellow lead
25A fuse (N504M.3) Yellow wire
Yes
Yes
Is there 12 volts DC at
Is there 12 volts DC at
input of mode selector
input of mode selector
switch?
switch?
(Terminal 4a, Red wire)
(Terminal 4a, Red wire)
Yes
Yes
Is there 12 volts DC at
Is there 12 volts DC at
output of mode selector
output of mode selector
switch?
switch?
(Terminal 4b, Yellow wire)
(Terminal 4b, Yellow wire)
Yes
Yes
Is power indicator light
Is power indicator light
on?
on?
No
No
Are indicator wires
Are indicator wires
properly connected per
properly connected per
wiring diagram?
wiring diagram?
No
No
Properly connect and or
Properly connect and or
repair wiring
repair wiring
www.norcold.com
Dépannage, suite
Models
Models
N304M.3,N404M.3,N504M.3
N305, N305.3, N306, and N306.3
Refrigerator will not operate in DC
Refrigerator will not operate in DC
Is mode selector switch in
Is mode selector switch in
the DC position?
the DC position?
Is DC power indicator light
Is DC power indicator light
No
No
Ensure red wire of
Ensure red wire of
fuse is connected
fuse is connected
to HC+ terminal
to HC+ terminal
No
No
OR
OR
Ensure yellow wire
Ensure yellow wire
of fuse is
of fuse is
connected to HC+
connected to HC+
terminal
terminal
Replace fuse
Replace fuse
No
No
Correct wiring/
Correct wiring/
connection
connection
No
No
between fuse and
between fuse and
selector switch
selector switch
(Red Wire)
(Red Wire)
Replace mode
Replace mode
No
No
selector switch
selector switch
Replace power
Replace power
Yes
Yes
indicator light
indicator light
mode
mode
Turn mode
Turn mode
No
No
selector switch to
selector switch to
DC and start up.
DC and start up.
Yes
Yes
on?
on?
Is DC voltage at input of
Is DC voltage at input of
Yes
Yes
Yes
Yes
SERVICE MANUAL / MANUEL D'ENTRETIEN / MANUAL DE SERVICIO
33
Resolución de problemas (cont.)
Yes
Yes
DC heater?
DC heater?
Yes
Yes
(Yellow Wires)
(Yellow Wires)
Repair wiring/connections:
Repair wiring/connections:
Yellow wire between selector
Yellow wire between selector
No
No
switch (terminal 4b) and heater
switch (terminal 4b) and heater
or
or
yellow heater wire connection
yellow heater wire connection
at terminal block terminal HC-
at terminal block terminal HC-
Replace heater
Replace heater

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

N306N305.3N306.3

Tabla de contenido