CAUTION!:
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION!:
POUR EVITER LES RISQUES DE DECHARGES ELECTRIQUES, NE PAS OUVRIR LE COUVERCLE.
CET APPAREIL NE COMPORTE AUCUNE PIECE SUSCEPTIBLE D'ETRE REPAREE PAR VOS SOINS. FAITES
TOUJOURS APPEL A UN TECHNICIEN QUALIFIE POUR TOUTE REPARATION.
MAINS INPUT
MAINS FUSE
100V~50/60Hz
230V/240V - T2AL 250V
N16549
300 WATTS
100V/120V - T5AL 250V
1
2
5. To store the desired selection press the Super Crunch (11) Select switch. The
Super Crunch Select LED (10) will flash quickly four times when the operation is
complete. The unit will then revert to normal operation, and will respond only to
Program Changes on the newly selected MIDI Channel.
MIDI Dump Out
You may wish to back up the MIDI channel select settings so you can transfer them
to another amplifier, for example. To do this you will need a MIDI Sysex librarian,
which is usually a piece of software running on a PC or MAC with a suitable MIDI
interface.
1. The unit must be in standby (Power (24) on and Standby (23) off), with no lead
connected to the Input jack and the MIDI Thru on the rear of the amplifier
connected to the MIDI In of the MIDI interface.
2. Simultaneously press and hold the Warm Clean (5) and Super Crunch (11) Select
switches. After 2 seconds the LED for Crunch (8) will flash continuously to
indicate that the unit is in MIDI Dump Mode.
3. Prepare the receiving equipment for the transfer. For example, if using a MIDI
Sysex librarian this must be put into file receive mode.
4. Start the file transfer by pressing and quickly releasing the Crunch (9) Select
switch. During the file transfer the Crunch Select LED (8) will flash quickly. When
the flashing stops the transfer operation is complete and the amplifier will revert
to normal operation. The file should be saved as a MIDI System Exclusive file.
MIDI Dump In
To load in previously saved Program Change assignments:
1. Connect the MIDI Out of the MIDI recording device to the MIDI In on the rear of
the amplifier and use the MIDI Sysex librarian to send the previously stored MIDI
System Exclusive file.
The amplifier overwrites the current Program Change assignments with the new
ones. If the operation completes successfully all four channel LEDs flash quickly four
times. If the dump is unsuccessful or incomplete the four LEDs will flash slowly in an
alternating pattern and then the unit will revert to normal operation.
Note: During reception of the System Exclusive file the amplifier will temporarily
cease to pass data to the MIDI Thru socket.
14
WARNING!:
SHOCK HAZARD. DO NOT OPEN. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. THIS APPARATUS MUST BE EARTHED.
AVIS!:
RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR. POUR EVITER LES RISQUES D'INCENDIE ET DE
DECHARGES ELECTRIQUES, N'EXPOSEZ JAMAIS CET APPAREIL A L'HUMIDITE OU A LA PLUIE. CONNECTER CET
APPAREIL A LA TERRE.
H.T. FUSE
FOOTSWITCH
THRU
This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
T1AL 250V
received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
3
4
MIDI
IMPEDANCE
SPEAKER OUTPUTS
8Ω
4Ω
16Ω
IN
CONNECT SPEAKERS BEFORE USE
OUTPUT: 100 WATTS RMS
WARNING!:
RISK OF HAZARDOUS ENERGY
AVIS!:
ENERGIE ELECTRIQUE DANGEREUSE!
5
6
7
8
Restoring Factory Settings
To return the amplifier to its factory default state:
1. With the amplifier Power off, press and hold in the Warm Clean (5) and Super
Crunch (11) Select switches.
2. While holding in the switches turn on the amplifier. After 2 seconds all channel
select LEDs flash once to confirm the factory defaults have been restored.
Rear Panel
1. Mains Input
The supplied detachable mains lead is connected here. The lead should only be
connected to a power outlet that is compatible with the voltage, power and
frequency requirements stated on the rear panel. If in doubt get advice from a
qualified technician.
2. Mains Fuse
The value of the Mains Fuse is specified on the rear panel. Never use a fuse of the
incorrect value or attempt to bypass it.
3. H.T. Fuse
The value of the H.T. Fuse is specified on the rear panel. Never use a fuse of the
incorrect value or attempt to bypass it.
4. Footswitch
The supplied footswitch is connected here. The footswitch enables you to switch
between the Bright Clean, Warm Clean, Crunch and Super Crunch modes.
5. MIDI Thru
Any MIDI data received at the MIDI In socket is passed out of the MIDI Thru socket
so that other MIDI devices can be placed in a chain. The MIDI Thru socket also
serves as a way of dumping Channel Select/Program Change data to a suitable MIDI
storage device. Refer to the MIDI Channel Switching section for more details. Always
use a good quality MIDI lead.
6. MIDI In
If channel switching using MIDI is required, connect the MIDI device here. Refer to
the MIDI Channel Switching section for more details. Always use a good quality MIDI
lead.
EMULATED OUTPUT
Designed and Engineered by
Blackstar Amplification Ltd
Northampton, England
Made under license in Korea
WARNING!:
DO NOT OBSTRUCT VENTILATION GRILLES
ATTENTION!:
NE PAS OBSTRUER LES GRILLES DE VENTILATION
9
MODEL: S1-100
EFFECTS LOOP
LEVEL
+4dBV
-10dBV
RETURN
SEND
10
11
12
15