GB
Indicator signals
A. Limit positions for the hose should be set.
B. The hose moves downwards or upwards.
C. The fan is in operation.
D. Stand by. Power on.
A
red light
B
red light
Declaration of conformity
We, AB Ph. Nederman & Co., declare
under our sole responsibility that the
Nederman product:
- Exhaust hose reel serial 865 with
accessories to which this declaration
relates, are in conformity with the following:
Directives
2006/42/EC, 2006/95/EC, 2004/108/EC
Standards
EN ISO 12100-1-2, EN61000-6-4, EN 61000-6-2,
EN 55011 class B
The product manager, Roger Knutsson, is responsible
for the technical documentation.
AB Ph. Nederman & Co.
P.O. Box 602
SE-251 06 Helsingborg
Sweden
2009-11-26
Roger Knutsson, Product manager
10
EXHAUST HOSE REEL
C
blue light
D
blue light
Service instruction
Check the following points at least once a year.
Take action when necessary.
• Check that the reel is secured in the ceiling or
on the wall.
• Check the duct connections for leakage.
• Check the hose for damage.
• Check the coiling function of the hose. Setting the
limit positions fo hose, see page 9.
• Check the hose connection in the connection piece
inside the drum.
• Check that there is enough suction in the exhaust
hose.If not, check the fan's rotation direction and/or
damper function. Check the hose for holes.
WARNING!
Risk of personal injury!
and repair work inside the system (for
example hose / nozzle)
Spare parts
When ordering parts always state:
• Part no. and control no.
(from the type label of the product).
• Detail no. of the spare part and the name
(as per list below).
• Quantity of the parts required.
1
Drum end plate, swivel side
2
Drum end plate, motor side
3
Inner hose
4
Connecting piece
5
Gable/Bearing, swivel side
6
Motor side, complete
13
Mounting brackets, pair
15
Connecting hose
17
Hose guide
20
Motor, complete
21
Indicator arm, complete
22
Remote control
23
Pendant control