GENERAL PRESENTATION
This product complies with the "safety, specific rules for powering vertically opening garage doors in residential use" requirements (standard EN
60335-2.95). When installed in line with these instructions and in compliance with the "Installation Checklist", the product will be compliant with
standards EN 13241-1 and EN 12453.
The instructions referred to in the installation manual and instructions for use of this product are designed to prevent damage to property and personal
injury along with compliance with the above standards. Failure to comply with these instructions absolves Somfy from any liability resulting from
damage that may be caused. Dexxo Pro is a product that must be installed inside the garage with an integrated back-up control system.
Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999/5/CE. A declaration of
compliance is available from the web site at www.somfy.com/ce (Dexxo Pro io). This product is suitable for use in the European Union and in Switzerland.
SAFETY INSTRUCTIONS
Caution
These are important safety instructions. Always follow the instructions, incorrect installation may lead to serious injury.
Safety instructions
Before installing the motor drive unit, remove all unessential lines or chains and switch off all equipment that is not essential for motorised door operation.
Before installing the motor drive unit, make sure that the door is in good mechanical condition, that it is properly balanced and that it opens and closes correctly.
Locate all control systems at least 1.5 metres above floor level, making sure that they are visible from the entrance to the garage but safe from moving parts.
Position the manual release cord no more than 1.8 metres above floor level.
Where a removable release mechanism is used, we recommend storing it close to the door.
Fix the label describing the manual release procedure close to the release mechanism.
Fix the warning labels describing the hazards of door motion close to any fixed control mechanisms installed and make sure that the labels are clearly
visible to the user.
After installation, make sure that the mechanism is correctly adjusted and that the motor drive unit reverses its motion when the door encounters an
obstacle that is at least 50 mm from floor level.
After installation, make sure that no part of the door overhangs an area accessible to the public.
After installation, make sure that the motor drive unit inhibits or stops the door opening motion when the door is loaded down with a 20 kg weight
attached to a central position of the door's bottom edge.
PRODUCT DESCRIPTION
Product components
Key
Number
Description
1
1
Motor head
2
1
Motor cover
3
1
Built-in light cover
4
1
Lintel bracket
5
1
Door bracket
6
2
Ceiling bracket
7
2
Motor head bracket
8
1
Manual release cord
9
1
Link arm
10
1
Travel stop
11
4
Chain retainer pad
12
1
Power cable
13
2
Hex. head M8x16 bolt
Area of application
Types of doors (Fig.2)
A: Projecting up and over door.
B: Sectional door:
- if the door's upper profile is a specific one, use the "sectional door mounting bracket" ref.: 9009390.
- if the door surface exceeds 10 sq. metres, use the "sectional door adapter" ref.: 2400873.
C: Sideways opening sliding door:
- for side wall mounting, use:
- a belt transmission rail
- an "adjustable cranked arm" ref.: 9014481.
- for ceiling mounting, use:
- an "articulated arm" ref.: 9014482.
D: Swinging door. Use the swinging door kit, ref.: 2400459.
E: Semi and non projecting door. Use:
- a high performance transmission rail
- "the semi and non projecting door kit" ref.: 2400458.
Some doors of this type may prove impossible to automate. Contact SOMFY's technical department.
Fig.
1
Fig.
2
Key
Number
Description
14
4
Hex. head M8x12 bolt & washer
15
6
HU8 nut
16
2
Shaft
17
2
Circlips
19
4
Self-shaping Ø 4x8 screw
20
2
Special screw for plastic Ø 3.5x12
21a
1
Single part rail
21b
1
Two part rail
21b1
1
Sleeve
21b2
8
Self-shaping Ø 4x8 screw
Keytis 4 io remote control
22
1
23
1
230 V 40 W E14 socket light bulb
24
1
Antenna
2