MAINTENANCE
Replacing the bulb in the light unit (Fig. 20)
[1] [2]. Remove the light cover.
[3] [4]. Unscrew and replace the defective light bulb.
[5] [6] [7]. Refit the light cover.
Use a 230 V 40 W E14 socket light bulb.
Checking
The obstacle detection function
Every six months, check that the door reverses direction when an obstacle prevents the door from closing (at least 50 mm above floor level).
The safety mechanisms (cells, pedestrian door contact, sensor bar)
Check correct operation every six months (refer to page 5).
The back-up battery
To ensure optimum battery life, we recommend that the power to the motor is switched off and the door is operated for a number of cycles using
battery power (three times a year).
TECHNICAL SPECIFICATIONS
Basic technical specifications
Mains power supply
Power consumption on standby
Max. power consumption
Traction force
Use
Number of channels that can be memorised
Somfy radio frequency
Integrated light
Remote controlled lighting
Operating temperature
8
20
Dexxo Pro 800 io
230 V - 50 Hz
5 W
600 W (with 500 W remote controlled lighting)
800 N
20 cycles per day with a standard rail (tested for 36,500 cycles)
50 cycles per day with a high performance rail (tested for 90,000 cycles)
Situo io : 6
868 - 870 MHz
230 V / 40 W max. E14 socket
230 V / 500 W max. Class 2
-20 °C / +60 °C
Dexxo Pro 1000 io
1000 N
Others: unlimited