1) INTRODUCTION:
The electronic control card is suitable for the control of sectional doors, counterweight type overhead doors and spring type overhead
doors, operated by the NICE SPIDER 6060 and 6080 24V electromechanical actuators with 24 Vdc motors.
The control card can provide "Hold to run control", "semi-automatic" and "automatic" modes of operation for these units.
When the door is in operation, movement will be interrupted by activation of the safety inputs (stop and photocell).
Open and close positions are set with limit switches and braking during closing will reduce speed and noise at the end of the
manoeuvre.
The 433.92 Mhz radio receiver built into the control unit is suitable for the Flo1, Flo2, Flo4 and Very VE transmitters; the code is
memorised with the self-learning technique.
As an alternative to the built-in radio the unit will accept any of the range of plug-in Nice radio receivers
The unit has been designed to guarantee maximum reliability, safety and flexibility of use
1.1) DESCRIPTION:
IMPORTANT - Before starting to install the unit read all of the instructions carefully!
Quick Reference Chart
Fig. 1
16
17
1
2
3
4
5
: Invisible part, covered by the case
2) INSTALLATION INSTRUCTIONS:
Remember there are specific standards that have to be strictly followed regarding the safety of electrical installations and
automatic gates and doors!
As well as the legal requirements and standards that must be adhered to, please take note of the following points to ensure maximum
safety and reliability in your installation.
• Prior to installing check the surrounding environment. Carefully evaluate any hazards there could be from physical damage (transiting
vehicles, parts of trees falling etc.,), possible contact with foreign bodies (insects, leaves ...), flooding hazards or any other
exceptional events.
• Make sure that the mains voltage is the same as that given on the rating plate and in this manual.
• Check there are suitable electrical protections against short circuits and proper earthing on the mains supply.
• Remember that SPIDER has mains voltage running through it ( electrocution hazard, fire hazard ... ).
• Take care with the control unit, parts may be subject to damage if subjected to careless handling or high humidity etc.
• Make sure you have all the necessary materials and that they are suitable for this kind of use.
1: Programming button
15
14
2: STEP-BY-STEP BUTTON ( PP )
3: Dip Switch to select functioning modes
4: Selection of slowing down speeds
5: Trimmer to adjust maximum opening force
6: OK LED
7: Trimmer to adjust maximum closing force
13
8: Terminal board for connection of device inputs and outputs
12
9: LED signalling input state
11
10: Terminal for the aerial if the alternative radio is used on plug 11
10
11: Plug for alternative radio receiver
9
12: Courtesy light
13: LED signalling limit switch state
14: Coupling for the limit switches
15: Terminal board for connecting the motor
16: Coupling for the power transformer
6
7
8
17: Rapid low voltage fuse (6060=5A) (6065=1A) (6100=1A)
English