install the check valve before installing the
hose and ports. The check valve for the [1
1/8" or 1 ¼"] model will include a stainless
steel washer and a flapper. To install the
check valve, place stainless steel washer
into the discharge area of pump. Next
place the Nitrile flapper over the washer.
Then thread on the port on to pump's dis-
charge. Tighten port until port is bottomed
out with pump body.
For ¾" model install check valve such that
the tapered end is towards the direction of
flow. To install check valve, remove gasket
in Duraport and replace the gasket with
the check valve which also acts as the gas-
ket. Save the old gasket in case you intend
to not use the check valve at a later time.
Make sure to avoid loops or bends in the
hose. Support hose if necessary. It is im-
portant that the hose be constantly rising
and not be allowed to dip below the outlet
port as this may cause an airlock situation.
For maximum performance use smooth
bore, reinforced hose.
NOTE: The check valve supplied with your
Ultima Bilge pump is used to prevent the
backflow of water. The utilization of the
check valve requires you to be mindful of
its functionality. The check valve material is
made of Nitrile material to be used for wa-
ter applications only. Also, the check valve
will reduce the flow of the pump. If flow is
critical to the application of the pump, it
is recommended that the check valve not
be used. Also, when winterizing your boat,
remove the check valve to avoid ice forma-
tion and/or degradation of the check valve.
8
Place fingers on circles to test the
pump
Leave 1" of
clearance bet-
ween sensor
and any object
nearby
Mounting block
Wiring Instructions:
Refer to wiring diagram below. Use appro-
priate sized connectors for 16 Gauge wire.
The wiring connections should be made
with water resistant permanent terminals.
Liquid electrical tape should be used to
coat terminals. The mount connections
should be above the highest water level.
The warranty will become void on this
product if any electrical cord is cut back
more than 3 inches, if electrical splices be-
come submerged, failure to properly fuse
or if pump is installed contrary to instruc-
tions or warnings.
You may install a three way switch panel
that will allow the pump to be in manual
or automatic mode. Make sure to fuse the
pump. The fuse holder should be between
positive battery terminal and three way
panel switch. Make sure to use the appro-
priate fuse size for the models. To check
the operation of the pump, place two fin-
gers over the raised circular areas in the
back of the pump. After a short delay [5
seconds], the pump should turn on. If you
remove your finger from the top circle, the
pump should remain on. If you remove
both fingers, the pump should turn off.