The diagram below shows the order of selection using the rotary switch of the
FCT (F1) function.
4.2.5.2

The F2 function

This function enables the user to vary the frequency of the sound subcarrier
from 4 to 9 MHz, in 62.5 kHz steps.
This function is necessary if the user wants to vary the frequency of the sound
subcarrier related to the measurement of the V/A ratio (see Point 4.2.6). The instrument
takes as the default frequency the value configured in the factory (or a customized
configuration through RM-004). However, with the F2 function the user can vary the
sound subcarrier value manually, from 4 to 9 MHz.
Example 11. Changing the sound subcarrier frequency from the standard value to 5.74
(Zweiton Stereo).
F2
Page 20
Figura 8.- Menú de la función F1