• Set the stove at a firm and stable floor in a room that is suitable for the stove to operate in, compliant
with building regulations, and then level with adjustable feet (Fig. 4).
Conditions for connection to mains:
• Make sure that the mains voltage corresponds to the voltage indicated on the rating plate of the
appliance (5 Pos. 3)
• To connect the appliance to the mains, connect the power cord to the terminal box at the bottom of
the appliance (Fig. 5 Pos. 2). The power cord with plug is NOT part of the kit and must be purchased.
• The device must be connected to an equipotential equalization system using the equipotential screw
(Fig. 5 Pos. 1) located at the bottom of the device at the terminal box. It is marked with the following
symbol:
3
2
1
The power cord should be flexible, oil-resistant, earthed, polychloroprene-coated - it can be made by the
manufacturer and available from him or in specialist repair shops!
• Only an authorized technician with a certificate for electrical works may connect the device to the
electrical grid.
• The appliance should be connected to a 400V 50Hz three-phase socket equipped with a circuit breaker
In=30mA by means of a plug or directly to the power supply.
To connect the device to an electrical equalizing system:
• loosen the nut on the screw
Figure 4. Leveling the device
3
1
2
Figure 5. Rear view of unit
PE – protective wire (yellow-green)
N – neutral wire (blue)
L1, L2, L3 – phase wires (other colors)
Figure 6. Connecting the unit to the mains.
- 20 -
Rear panel components:
1. Equipotential bolt
2. Terminal box
3. Rating plate