Descargar Imprimir esta página

Sime MURELLE HE 35 R M Manual Del Usuario página 104

Ocultar thumbs Ver también para MURELLE HE 35 R M:

Publicidad

Idiomas disponibles

Idiomas disponibles

Codice/Code 8111200
Modello/Model MURELLE HE 35 R (M)
Matricola/Serial n. 9999999999
PAR 1 = 3 (G20) / 11 (G31)
PAR 2 = 5
with drain trap contains water (this
check is particularly important if the
generator has not been used for exten-
ded periods of time).
If necessary, the drip plate can be filled
using the tap provided (fig. 20).
4.5. 1
Chimney sweep function (fig. 21)
To check boiler combustion, press the
installer's key
for a few seconds. The
chimney sweep function will switch on and
will continue for 15 minutes.
104
ATTENTION
Before removing or refitting the front
panel of the boiler, open the small
upper plastic door.
From that moment, the boiler will start
working in heating mode at maximum
power, with cut off at 80°C and re-ignition
at 70°C (ATTENTION! Temperature may
reach excessive values when using unpro-
tected low temperature plants. Before
activating the chimney sweep function
make sure that the radiator valves or
eventual zone valves are open).
The test can also be carried out with the
boiler working in D.H.W. mode.
For this, after activating the chimney sweep
function, open one or more hot water fau-
cets. Under these conditions, the boiler will
Fig. 19
Fig. 20

Publicidad

loading