%1
Fig. 4
7 WELDING
Welding Synergic Pulsed MiG LED AP on.
Select the PRG number based on the wire diameter to be
used, the type and quality of the material, and the type of
gas, using the instructions located inside the wire feeder
compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
5.2.3The welding parameters are set by means of knobAI.
Synergic MiG Welding LED AQ on.
Select the PROG number based on the wire diameter to
be used, the type and quality of the material, and the type
of gas, using the instructions located inside the wire feed-
er compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI.
Conventional MiG Welding LED AR on.
Select the PROG number based on the wire diameter to
be used, the type and quality of the material, and the type
of gas, using the instructions located inside the wire feed-
er compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI. and AN respectively.
&$
8 ACCESSORIES
8.1 MIG WELDING TORCH ART. 1242
Air-cooled CEBORA MIG welding torch 280 A 3,5.
8.2 PUSH-PULL UP/DOWN WELDING TORCH, airr
cooled, ART. 2003.
8.3 Trolley, art. 1656, for transportation of the power
source
8.4 Kit for Ø 300 mm (15 kg) wire spools, art. 114
9 MAINTENANCE
Any maintenance operation must be carried out by qua-
lified personnel in compliance with standard CEI 26-29
(IEC 60974-4).
9.1 GENERATOR MAINTENANCE
In the case of maintenance inside the machine, make
sure that the switch L is in position "O" and that the
power cord is disconnected from the mains.
Even though the machine is equipped with an automatic
condensation drainage device that is tripped each time
the air supply is closed, it is good practice to periodically
make sure that there is no condensation accumulated in
the water trap J (fig.1).
It is also necessary to periodically clean the interior of the
machine from the accumulated metal dust, using com-
pressed air.
9.2
PRECAUTIONS AFTER REPAIRS.
After making repairs, take care to organize the wiring so that
there is secure insulation between the primary and secon-
dary sides of the machine. Do not allow the wires to come
into contact with moving parts or those that heat up during
operation. Reassemble all clamps as they were on the origi-
nal machine, to prevent a connection from occurring
between the primary and secondary circuits should a wire
accidentally break or be disconnected.
Also mount the screws with geared washers as on the ori-
ginal machine.
15