− there are any leaks.
− the minimum volumetric control (pressure
gauge) is functioning correctly.
− Suction performance check.
A log for annual general inspections should
be kept. This must clearly show the date of
the inspection, identified faults and the name
of the inspector. If required, the machine
should undergo an overhaul!

15 Overhaul

If required, an overhaul must be carried out.
Written records should be made of the work
carried out during the overhaul.

16 Repairs

Repairs to the dust extractor should only
be carried out by qualified technicians!
Elektra Beckum machines requiring repairs
can be sent to the address specified on the
spare-parts list. Please enclose a description
of the fault with the power tool.

17 Environmental Protection

Elektra Beckum packaging is 100%
recyclable. Worn-out devices and
accessories contain large amounts of
valuable raw materials and plastics, which
can also be recycled.
These operating instructions are printed on
chlorine-free bleached paper.

18 Technical Specifications

Changes due to technological progress
reserved.
Operating mode:
Continuous operation
Current type:
1-phase alternating current
Frequency:
Rated consumption:
P
1
Output performance:
P
Mains voltage:
Power consumption:
Degree of protection:
Idling speed:
Diameter of extractor connection piece:
mm
Dimensions:
1085 x 655 x 1974 mm
Weight:
Filtering surface:
Dust collection volume:
Rated volumetric flow:
V
= 775 m
rat
Related vacuum:
(upstream of ventilator)
Minimum volumetric flow:
V
= 565 m
min
Related vacuum:
(upstream of ventilator)
Max. vacuum:
Typical A-weighted sound level:
Sound-pressure level:
L
=78 dB(A)
pA
Sound output level:
L
=94 dB(A)
WA
Wear ear protection!
Sound level as per MRL, Appendix 1,
Point 1.7.5 f, in free field, distance 1 m,
height 1.6 m.
Measured values determined in conformity
with EN 23744.
The stated technical specifications are
subject to tolerances (as specified in the
respective current standards).
50 Hz
=1.47 kW
=1.1 kW
2
~230 V
6.4 A
IP 54
2830 rpm
100
97 kg
2
3.45 m
135 l
3
/h
2095 Pa
3
/h
1572 Pa
2430 Pa