TROUBlESHOOTING CODES

CODE POSSIBlE CAUSE
1
Pressure Switch (I) does
not shut off motor when
compressor reaches
cut-out pressure
2
Pressure Switch (I)
cut-out too high
3
Tube fittings are not tight
enough
4
Defective air tank
5
Leaking seals
6
Defective Safety Valve
(G)
7
Regulator is not adjusted
correctly for accessory
being used
8
Prolonged excessive
use of air
9
Compressor is not large
enough for accessory
10
Hole in air hose
11
Check Valve (F) restricted Contact a BOSTITCH factory service center or a BOSTITCH
12
Air leaks
13
Regulator is damaged
14
Motor overload protection
switch has tripped
15
Tank pressure exceeds
Pressure Switch (I) cut-in
pressure
16
Extension cord is wrong
length or gauge
17
Loose electrical
connections
18
Possible defective motor
19
Paint spray on internal
motor parts
POSSIBlE SOlUTION
Set the On/Off switch to OFF, if the unit does not shut off
contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Tighten fittings where air can be heard escaping. Check
fittings with soapy water solution. Do Not Overtighten.
Air tank must be replaced. Do not repair the leak.
Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank
can rupture or explode.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Operate Safety Valve (G) manually by pulling on ring. If
valve still leaks, it must be replaced.
It is normal for some pressure drop to occur when an
accessory is used, adjust the regulator as instructed in
Regulator
under Features if pressure drop is excessive.
NOTE:
Adjust the regulated pressure under flow conditions
while accessory is being used.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the
CFM or pressure supplied by your air compressor, a larger
compressor is needed to operate accessory.
Replace air hose.
authorized service center.
Tighten fittings.
Replace.
Motor Overload Protection
Refer to
If motor overload protection trips frequently, contact a
BOSTITCH factory service center
or a BOSTITCH authorized service center.
Motor will start automatically when tank pressure drops
below cut-in pressure of Pressure Switch (I).
Check for proper gauge wire and cord length. Refer to the
Extension Cords paragraph in the Installation section.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center. Do not operate the compressor in
the paint spray area.
See flammable vapor warning.
15
under Features.