RECOVERY TANK REMOVAL
To check the batteries, or to perform other procedures, it may be necessary to remove the recovery tank (31) as shown below.
1.
Empty the recovery tank (31) as shown in the relevant paragraph.
2.
Drive the machine on a level fl oor.
3.
Make sure that the switches (65 and 66) are turned to "0".
4.
Disconnect the vacuum hose (22) from the squeegee (11).
5.
Disconnect the recovery water drain hose (16) from the bracket (17).
6.
Open the cover (6).
7.
Grasp the recovery tank (A, Fig. 5) in the area (B) and slightly raise it.
8.
Disconnect the vacuum hose (C) from the tank, then remove the tank (A) with the hoses (D) and (E).
MACHINE LONG INACTIVITY
If the machine is not going to be used for more than 30 days, proceed as follows:
1.
Perform the operations described in the After Using The Machine paragraph.
2.
Remove the recovery tank (31) according to the procedure shown in the previous paragraph, then disconnect the battery
negative terminals (50).
3.
Install the recovery tank (A).
4.
Store the machine in a clean and dry place.
FIRST PERIOD OF USE
After the fi rst period of use (fi rst 8 hours) it is necessary to check the fi xing and connecting parts of the machine for proper
tightening. Check the visible parts for integrity and leakage.
B
A
C
D
Figure 5
Micromatic™ M17B
INSTRUCTIONS FOR USE
E
909 5853 000(3)2008-11
ENGLISH
S310233A
15