TFA_No_30.3034.01_Anl_01_13
RATIO
– Wireless thermometer
No DCF reception
Incorrect display
12. Waste disposal
This product has been manufactured using high-grade materials
and components which can be recycled and reused.
Never dispose of empty batteries and rechargeable
batteries in household waste.
As a consumer, you are legally required to take
them to your retail store or to appropriate collec-
tion sites depending on national or local regulations
in order to protect the environment
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the
EU Waste Electrical and Electronic Equipment Direc-
tive (WEEE).
Please do not dispose of this instrument in household
waste. The user is obligated to take end-of-life devices
to a designated collection point for the disposal of
electrical and electronic equipment, in order to ensure
environmentally-compatible disposal.
13. Specifications
Basic unit:
Measuring range
Indoor temperature:
18
25.01.2013
11:51 Uhr
➜ Wait for attempted reception
during the night
➜ Choose another place for the
instrument
➜ Check if there is any source of
interference
➜ Restart the device as per the
manual
➜ Set the clock manually
➜ Change batteries
0...+60°C (+32...+140°F)
Seite 10
RATIO
– Wireless thermometer
Precision:
Power consumption:
Dimensions:
Weight:
Outdoor transmitter:
Measuring range
Outdoor temperature:
Precision:
Transmission frequency:
Distance range (free field):
Power consumption:
Dimensions:
Weight:
±1°C
2 x 1,5 V AA
(Batteries not included)
68 x 29 (78) x 113 mm
86 g (instrument only)
-40...+65°C (-40...+149°F)
±1°C
433 MHz
100 m
2 x 1,5 V AAA
(Batteries not included)
36 (46) x 16 (30) x 120 (123) mm
33 g (instrument only)
19