AUtec Modular Serie Manual De Usuario página 20

Ocultar thumbs Ver también para Modular Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTRUCTIONS FOR DOCUMENT MANAGEMENT
The following minimum documentation is supplied with each radio remote control:
- transmitting unit manual
- receiving unit manual
- battery charger manual
- a CE conformity declaration
- a guarantee certificate
- the radio remote control technical data sheet
- the enclosed "Limitations & Authorisations".
Make sure that the following documents have been supplied: if they are not, re-
quest them from Autec. Please specify the radio remote control serial number.
The conditions of the radio remote control guarantee are given in the "Certificate of
Guarantee" contained in this manual.
The electronic components which have a 3 year guarantee are: E16STXEU_,
E16SRXEU_ and E16SCHEU_.
The technical data sheet shows the wiring system between the receiving unit and
the machine. It should be compiled and checked by the installer, who has the re-
sponsibility of correct wiring. Once all necessary checks have taken place the in-
staller must sign the technical data sheet, which must be kept with the user's
manual (always keep a copy of this data sheet in case it is needed for administra-
tive purposes).
The radio remote control identification and approval data is given on plates that are
on both the transmitting unit and the receiving unit.
The plates MUST NOT be removed from where they are placed or damaged oth-
erwise the warranty will be forfeited.
Frequency band .................................................................... 434.040 - 434.790 MHz
....................................................................................... * or 433.050 - 434.790 MHz
....................................................................................... * or 869.700 - 870.000 MHz
Programmable radio channel ......................................... 16 (434.040 - 434.790 MHz)
....................................................................................... 32 (433.050 - 434.790 MHz)
....................................................................................... 12 (869.700 - 870.000 MHz)
Channel spacing............................................................................................... 25kHz
Hamming distance................................................................................................... ≥8
Probability of non-recognition of error ...................................................... <10 exp-11
Typical working range ....................................................................................... 100 m
Time of reply to commands ......................................................................... < 100 ms
Time of reply to STOP................................................................................. < 100 ms
Passive emergency time ......................................................................... ** 0,5/1 sec.
* refer to the "Limitations & Authorisations" insert to select the permitted working band and paragraph 8 "Pro-
gramming" if setting is necessary.
** refer to paragraph "Programming" in the receiving unit manual, DIP nr. 1 settings.
Page 18 of 71
CERTIFICATE OF GUARANTEE
TECHNICAL DATA SHEET
IDENTIFICATION PLATES
MODULAR SERIES TECHNICAL DATA
2 - Introduction
LIMJNMU0

Publicidad

Tabla de contenido
loading

Tabla de contenido