9 MJ TRANSMITTING UNIT DIAGNOSTICS

If the "machine+radio remote control" system does not start, check if the problem is caused
by the radio remote control or the machine. Before carrying out any verifications, check the
functioning of the machine with the cable control panel:
- if it does not switch on, the problem lies with the machine itself
- if it does switch on, the problem lies with the radio remote control. In this case, proceed
as follows:
When START is
activated, is the red
LED lit steadily and
does the buzzer
sound?
NO
Does the red LED
blink and does the
buzzer sound?
NO
Does the green
LED blink?
NO
If the problem
persists
CALL
TECHNICAL
ASSISTANCE
LIMJNMU0
Is the STOP button
or one of the
YES
movement
actuator inserted?
Release it/them
The battery is dis-
charged: replace it
YES
with one that is
charged. Does it con-
tinue to blink quickly
and the buzzer sound-
ing?
NO
Carry out
YES
diagnostics checks
on the receiving
unit.
9 - MJ transmitting unit diagnostics
Is the led on with a
steady light?
NO
Clean the contacts
in the battery seat.
YES
Does it continue to
blink quickly and the
buzzer sounding?
NO
YES
YES
Page 27 of 71