C - iNSTALLATiON
3 - CONNECTIONs
• Do not increase the number of insulating screw joints or connectors on the connecting wire between the
doorplate and the monitor
• Keep the connecting wire between the doorplate and the monitor more than 50 cm away from any
electromagnetic interference (230 V cable, WiFi device, microwave ovens, etc.)
• You can connect and use the electric door release (not provided) with your doorplate, with or
without mechanical memory.
between the monitor and the doorplate (100m maximum)
to ensure good audio and video quality, it is advised to not use more than 100m of cable between the
intercom and the doorplate. Connect the wires as follows (incorrect wiring can damage the doorplate).
the cable's length determines which cable section is to be used:
Cable length
0 to 50 m
50 m to 100 m
between the doorplate and an electric latch (not included)
Use a 12V/0.5A maximum electric latch with or without mechanical memory.
For the connection between the doorplate and the door release, use a cable of this kind:
Cable length
0 to 50 m
between the doorplate and the automated gate (not included)
Section to use: Min. 0.75 mm2
10
eN
Colour video interCom
section to use
0.75 mm2
1.5 mm2
section to use
0.75 mm2