GB
3.5
Environmental protection
If batteries need to be replaced, please observe the following:
•
Return used GESIPA
•
Never discard used batteries into household waste, fire or into water!
Caution!
In all EU countries the relevant national regulations for implementing the EU guideline
shall apply.
•
In accordance with the EU Directive 2002/96/EC (WEEE), in Germany, this tool is regis-
tered under the WEEE Reg.-No. DE 45695505. If the tool has an 8-digit serial number it
can be returned free of charge to GESIPA
4.
Repairs
Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty pe-
riod should only be carried out by skilled technical personnel. Failure to observe the assembly
and setting procedures and operation by non-skilled personnel may result in serious damage
to the blind rivet nut setting tool. In case of doubt, always send in the blind rivet nut setting tool
to the supplier or to GESIPA
5.
Troubleshooting
5.1
Blind rivet nut does not screw on
Cause
Nut thread defective
Threaded mandrel A defective
Nut does not rest against nosepiece
Nut unscrews again
Battery switched off because it has been
idle for longer than 21 days
Battery discharged
26
rechargeable batteries to your dealer or to GESIPA
®
.
®
for correct disposal.
®
Corrective measures
Use new nut
Change threaded mandrel A
Threaded mandrel length x incorrect; adapt to
nut length (see Point 2.7.1)
While it is screwed on, hold the nut until the tool
stops
Keep switch K pressed until the tool stops
Place battery in the charger for 2 minutes
(see 3.4)
Charge battery, replace if necessary
(see Point 3.3/3.4)
for recycling.
®