Descargar Imprimir esta página

Kenmore 11072812101 Instrucciones De Instalación página 7

Secadora a gas de 29 pulg. (73,7cm)

Publicidad

Idiomas disponibles

Idiomas disponibles

Determine
Vent Lengfi_
1o Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns.
°gJ
2.
Determine vent length
The maximum length of the exhaust system depends upon:
The type of vent (rigid metal or flexible metal).
The number of elbows used.
Type of hood.
Recommended
hood styles are shown here.
2
(10.2
cm)
1. Louvered hood style
2. Box hood style
The angled hood style (shown following) is acceptable.
See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
Shorten the life of the dryen
Reduce performance,
resulting in longer drying times and
increased energy usage.
3.
Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in
the Vent Length CharL
The following char[ helps you determine your maximum vent
length based on the number of 90 ° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood
that you will use.
Vent Length Chart
Number of
Type of
Box or
Angled
90 ° turns
vent
Louvered
hoods
or elbows
hoods
O
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
Flexible metal
36 ft (11 m)
28 ft (8.5 m)
1
Rigid metal
54 ff (16.5 m)
48 ft (14.6 m)
Flexible metal
31 ft (9.4 m)
23 ft (7 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible
metal
27 ft (8.2 m)
19 ft (5.8 m)
3
Rigid metal
35 ft (1g.7 m)
29 ft (8.8 m)
Flexible
metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ff (6.4 m)
Flexible
metal
23 ft (7 m)
15 ft (4.6 m)
1. (Optional) Put on safety glasses and gloves.
2.
Install exhaust hood. Use caulking compound
to seal exterior
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4 in. (10.2 cm)
clamp.
4.
Run vent to dryer location. Use the straightest path possible.
See "Determine Vent Length." Avoid 90 ° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure
vent.
1o To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2.
Firmly grasp the body of the dryer (not the top or console
panel).
\\
\
Gently lay the dryer on the cardboard.
7