2.5 Function overview

The BMV factory settings are suitable for an average 12V/24V lead acid
battery system of 200Ah. The BMV can automatically detect the nominal
voltage of the battery system, so in most cases the only setting which will
need to be changed is the battery capacity (Cb). When using other types of
batteries please ensure that all the relevant specifications are known before
attempting to setup the BMV parameters.
2.5.1 Setup parameter overview
Name
Description
Cb
Battery capacity
Vc
Charged voltage
It
Tail current
Charged detection
Tcd
Charge efficiency
CEF
PC
Peukert exponent
Ith
Current threshold
Tdt
Time to go tA
Discharge floor
DF
(SOC relay)
ClS
Clear SOC relay
Relay minimum
RME
enable time
RDD
Relay disable delay
Alarm low voltage
Al
(buzzer)
Clear low voltage
Alc
Alarm high voltage
Ah
(buzzer)
Clear high voltage
Ahc
Alarm low SOC
AS
(buzzer)
Clear low SOC
ASc
Rl
Relay low voltage
Clear relay low
Rlc
voltage
Rh
Relay high voltage
10
Min.
20
0.0
0.5
time
50
factor
1.00
0.00
0.0
0.0
0.0
0.0
alarm
0.0
0.0
alarm
0.0
0.0
alarm
0.0
0.0
0.0
Default
200
13.2
4.0
1
3
90
1.25
0.01
0
3
50.0
90.0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Reso-
Max.
lution
9999
1
90.0
0.1
10.0
0.1
50
1
99
1
1.50
0.01
2.00
0.01
12
1
99.0
0.1
99.0
0.1
500
1
500
1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
Units
Ah
V
%
min.
%
A
min.
%
%
min.
min.
V
V
V
V
%
%
V
V
V