3.2 Historical menu
The BMV tracks multiple statistics regarding the state of the battery which
can be used to assess usage patterns and battery health. The historical
data can be viewed by pressing the select button when viewing the
monitoring menu.
Label
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13*
H14*
H15*
H16*
* BMV-602 Only
3.3 Nominal voltage detection
Although the BMV factory settings are chosen for a 12V battery system, the
BMV is able to automatically determine the nominal voltage. The BMV is
also able to adjust the charged voltage parameter without user intervention.
During charging, the BMV measures the current battery voltage, and uses
this to estimate the nominal voltage. The following table shows how the
nominal voltage is determined, and how the charged voltage parameter is
adjusted as a result.
18
Description
The depth of the deepest discharge.
The depth of the last discharge.
The depth of the average discharge.
The number of charge cycles.
The number of full discharges.
The cumulative number of Amp hours
drawn from the battery.
The minimum battery voltage.
The maximum battery voltage.
The number of days since the last full
charge.
The number of times the BMV has
automatically synchronized.
The number of low voltage alarms.
The number of high voltage alarms.
The number of low starter battery voltage
alarms.
The number of high starter battery voltage
alarms.
The minimum starter battery voltage.
The maximum starter battery voltage.
Units
Ah
Ah
Ah
Ah
V
V
V
V

Publicidad