Descargar Imprimir esta página

Victron energy BMV 600 Manual De Instrucciones página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BMV-602 ONLY
AlS:
Alarm low starter battery voltage (buzzer). When the starter
battery voltage falls below this value for more than 10 seconds a bell
icon appears on the display, the backlight flashes, and the buzzer
will sound. The buzzer and backlight-flashing can be turned off by
pressing any key; the bell-icon will remain on the display.
Clear low starter battery voltage alarm. When the starter battery
AlcS:
voltage rises above this value, the alarm is turned off. This value
needs to be greater than or equal to AlS.
AhS:
Alarm high starter battery voltage (buzzer). When the starter
battery voltage rises above this value for more than 10 seconds a
bell icon appears on the display, the backlight flashes, and the
buzzer will sound. The buzzer and backlight-flashing can be turned
off by pressing any key; the bell-icon will remain on the display.
AhcS:
Clear high starter battery voltage alarm. When the starter battery
voltage falls below this value, the alarm is turned off. This value
needs to be less than or equal to AhS.
RlS:
Relay low starter battery voltage. When the starter battery voltage
falls below this value for more than 10 seconds the alarm relay will
be activated.
RlcS:
Clear relay low starter battery voltage. When the starter battery
voltage rises above this value, the alarm relay will be de-activated.
This value needs to be greater than or equal to RlS.
RhS:
Relay high starter battery voltage. When the starter battery
voltage rises above this value for more than 10 seconds the alarm
relay will be activated.
RhcS:
Clear relay high starter battery voltage. When the starter battery
voltage falls below this value, the alarm relay will be de-activated.
This value needs to be less than or equal to RhS.
D VS:
Starter battery voltage display. Determines if the starter battery
voltage is available in the monitoring menu.
ShA:
Maximum rated shunt current. If using a shunt other than the one
supplied with the BMV, set this to the rated current of the shunt.
ShV:
The shunt output voltage at the maximum rated current. If using
a shunt other than the one supplied with the BMV, set this to the
rated voltage of the shunt.
16

Publicidad

loading

Este manual también es adecuado para:

Bmv 602