Remote Mode Commands
Cmnd
Passwd Format
FR
AT
PA
CF
RC
ST
Page 38
* FRnnnn<cr>
*?FR<cr>
* ATnn<cr>
*?AT<cr>
* PAnn<cr>
*?PA<cr>
* CFnn<cr>
*?CF<cr>
* RCnn<cr>
* STnn<cr>
Colour pattern generator GV-798+
Description
Sets a new PLL value
Reads present PLL value
It sets a new attenuation value
Read the present attenuation value
n: value of atten. in dB (hex) --->
00: 0 dB
3C: 60 Db
It sets active pattern
Reads present pattern
n: active pattern code --->
00: COMPLETE
01: FUBK
02: BARS100
03: BARS75
04: CCIR17
05: CCIR330
06: RED
07: GREEN
08: BLUE
09: DEM
0A: MBURST100
0B: MBURST50
0C: PLUNGE
0D: SINX
0E: RAMP
0F: DAMER
10: WHITE
11: CONV
12: WINDOW
13: STEPS10
14: STEPS5
15: CENTER
Sets the frequency or channel mode
Reads present C/F mode
nn = 0: frequency mode
nn > 0: channel set (nn-1)
01: CCIR
02: STD L
03: OIRT
04: FCC
Recovers the configuration memory content "nn"
nn: memory number in hex (between 00 and 1F)
Saves the present configuration to the
equipment memory position "nn".
nn: memory number in hex (between 00 and 1F)