MAINTENANCE AND USE MANUAL
It may be necessary to fire more than one cylinder containing the same or different linings
simultaneously, but at different temperatures (e.g. 3 C & B resin cylinders at 700°C, 2 ceramic alloys
cylinders at 850°C).
In this situation, we believe that the best way to proceed is to enter the melting data by occupying
two programs. Example:
Phase 2
Phase 3
Phase 4
Phase 5
•
Completely data-free.
Phase 2
Phase 3
Phase 4
Phase 5
•
Completely data-free.
The above-described data is purely indicative and does not refer to any particular fusion lining
available on the market. The numbers of phases used in Program n°1 may also vary
depending on technical needs.
The above is simply designed to illustrate a method that is both possible and at the same time secure,
simple and extremely practical.
The validity of this system lies in the fact that, after the 30-second buzzer informs the operator of the
end of Phase 5/Program n°1, the in-chamber temperature of 700°C is stabilised until fusion operations
for the first 3 C & B resin alloy cylinders are complete.
Afterwards, to exit Program n°1 and start Program n°2 to raise the temperature to 850°C,
proceed as follows:
A. press START-STOP (20); OFF reappears on the display (11).
B.
press PROG. SELECT. (12); "P" appears on the display (14).
C.
press n°2 on the numerical keypad; the number 2 appears on the display (14).
D. press PHASE; F appears on the display (15).
E.
press n°2 on the numerical keypad; the number 2 appears on the display (15).
F.
press START-STOP (20) again and the oven will immediately recommence working and
proceed towards 850°C.
FURNACE DM
EN
NOTES ON LINING FUSION SYSTEM
T
emperaTure
•
•
250 °C
700 °C
T
emperaTure
•
•
•
850 °C
PROGRAM N°. 1
i
nCreaSe raTe
•
•
6 °C/min
10 °C/min
PROGRAM N°. 2
i
nCreaSe raTe
•
•
•
10 °C/min
7.10
h
olding Time
•
•
20 minutes
30 minutes
h
olding Time
•
•
•
1 hour
167 of 272