Mounting and anchor characteristic values
Product information
Composite anchor V 4A M10
Approval ETA-05/0231: MKT V 4A
Mounting and anchor characteristic values
Thread
Drill hole diameter
Hole depth
Anchorage depth
Torque
Wrench size
Minimum fi xture thickness
Minimum distance to each
concrete edge
Mounting and anchor characteristic values
Anchor size
Drill diameter
d
=
[mm]
0
Cutting Ø
d
[mm] 12,5 14,5 18,5
cut
Hole depth
h
[mm]
0
Brush Ø
D
[mm]
Fixing torque
T
= [Nm]
inst
Wire brush
Curing time up to applying the load
Base material
Minimum curing time [minutes]
temperature [°C]
Dry concrete
+ 35
+ 30
+ 20
+ 10
+ 5
0
- 5
The valid approval as well as a mounting protocol can be
downloaded in the Internet from:
www.mkt-duebel.de
– download - Zulassungen/approvals - Verbundanker/chemical
anchor
– download - Arbeitshilfen - Montageprotokoll
094226_r_de_gb_fr_es_pt_it_drehkr_s
M10
M16
ø
= 10 mm
= 16 mm
d
= 12 mm
= 18 mm
0
h
(1)
= 90 mm
= 125 mm
0
h
= 90 mm
= 125 mm
ef
T
= 12 Nm
= 45 Nm
inst
SW
= 17 mm
= 24 mm
h
≥ 120 mm
≥ 175 mm
c
≥ 60 mm
≥ 100 mm
M10 M12 M16
M20
M24
12
14
18
25
25,5
28,5
90
110
125
170
210
13
16
20
27
12
20
45
100
150
Wet concrete
10
20
10
20
20
40
60
120
60
120
300
600
300
600
haacon hebetechnik gmbh – Telefon +49 (0) 9375 - 84-0 – Fax +49 (0) 9375 - 8466
Setting the anchors
Anchors are suitable under the following conditions:
– Installation by trained personnel under the supervision of the
site manager.
– As supplied by the manufacturer, without substitution of the
individual components.
– according to the preceding specifi cations, with suitable tools.
– before setting the anchor check the strength class of the
concrete, into which the anchor is to be setl.
– Perfect compression of the concrete, e.g. no cavities.
– Use of intact cartridges with valid date of expiry,
z Observe prescribed drill hole Ø and
the effective anchorage depth,
Observe defi ned edge and axis
distances without shortfall tolerance
Arrangement of the drill holes without
damage of the reinforcement, fi ll
incorrect drillings with mortar.
z Clean drill hole:
Completely remove water, which is
possibly in the drill hole. Clean the
drill hole by at least 1x blowing/1x
brushing/1x blowing/1x brushing.
Only use only clean brushes with the
correct brush diameter.
z Check before introducing the
cartridge, whether the resin fl ows
28
similar to honey with a lukewarm
cartridge.
30
z Drive the anchor rod right down
to the drill hole base by rotating,
striking (hammer drill).
z The setting markings of the anchor
rod must the fl ush with the edge of
drill hole edge and the annular gap
must be completely fi lled with mortar.
The temperature in the anchorage
base must be at least +5°C and may
not drop below 5°C during curing of
the grout.
Observe the prescribed waiting
period until applying the load.
z Fasten add-on part after the waiting
period with a torque wrench.
Observe indicated torque.