9 Annex
9.1 Technical data
Supply voltage
Motor output
Current input
Active cycle
Degree of Protection
ISO Class
Permissible ambient temperature
Max. fan output
Max. device output
Pressure, max.
Minimum exhaustion power
(volume flow monitoring activation threshold)
Extraction arm
Filtration area
Welding fumes separation efficiency class according to
EN ISO 15012-1 standard
Noise level at 1m distance according to DIN EN ISO
3744
Width
Depth
Height
Weight
Product number: 150 2464
Technical changes and errors reserved.
KEMPER ProfiMaster Instruction Manual - EN
- 68 -
see nameplate
1.1 kW
see nameplate
100%
IP 42
F
-10 / +40°C
1,800 m³/h
1,500 m³/h, without exhaust
arm
1,100 m³/h, with exhaust arm
2,250 Pa
700 m³/h
Nominal diameter 150,
length 2 m
length 3 m
length 4m
2
Main filter 17m
W3
72 dB(A)
655 mm
655 mm
976.5 mm
95 kg, without extraction arm
104 kg, with 2m extraction
arm
rev.:
2
Status as of: 05/2015