Pentair IntelliFlo WhisperFlo VF Guide D’iNstallation página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 274
16
Manual Mode (Continued)
b) T o set the flow:
Press the Select button to select it. The speed can be set from 400 to 3450 RPM (default 1000
RPM). To change the setting, see step 4 below.
4. To change the setting, press the Left and Right arrows to select which digit to modify, then use
the Up and Down arrows to change the selected digit.
5. When you are done, press the Enter button to save the changes. To cancel any changes, press the
Escape button to exit edit mode without saving.
6. Press the Start/Stop button (LED is on) to run IntelliFlo in "Manual" mode (LED is on). The
pump will ramp to the speed or flow settings just entered, and "Running" appears in the display.
To stop IntelliFlo, press the Start/Stop button (LED is off). "Stopped" appears in the display.
Note: While IntelliFlo is running in Manual mode, you can view the current power consumption
and what actual speed is being used.
7. Change Flow and Speed settings while the IntelliFlo is running:
settings "on the fly" while the pump is running, simply repeat steps 3 through 5.
• If "Set SPEED" is changed on the fly, IntelliFlo will immediatley ramp to the new speed
• If "Set FLOW" is changed on the fly, IntelliFlo will reprime before ramping to the new flow rate –
It takes the IntelliFlo about 60 seconds to two minutes to reach the commanded flow rate after it is
primed. This is best seen in Actual Speed status display
IntelliFlo VF Installation and User's Guide
®
MANUAL RPM
12:15
1 000.RPM
Set SPEED
STOPPED
Cursor hi-lights in
black
Use the Up and Down arrow button to scroll to the "Set FLOW" screen.
®
MANUAL RPM
12:15
1000. RPM
Set SPEED
+
STOPPED
+
Left/Right arrow
buttons to change
digit
®
MANUAL RPM
12:15
2000.RPM
Set SPEED
STOPPED
+
Press the Enter
button to save.
Press Start/Stop
To change the flow and speed

Publicidad

Tabla de contenido
loading

Tabla de contenido