Filter Cycle Settings - Pentair IntelliFlo WhisperFlo VF Guide D’iNstallation

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 274
29
Filter Menu (Continued)

Filter Cycle Settings

The table below shows the settings available in Filter Mode.
NAME
Clean Filter
Pressure
Turnovers
Per Day
Cycles per
Day
Start Cycle 1
Stop Cycle 1
Start Cycle 2
Stop Cycle 2
Start Cycle 3
Stop Cycle 3
Start Cycle 4
Stop Cycle 4
Based on "Pool Volume", "Turnovers per day" and the total number of hours for Cycle 1 + 2 + 3 + 4
the flow must be calculated:
PoolVolume
"
Flow
=
Cycle
Note: Only enabled cycles are included in the calculation
IntelliFlo VF Installation and User's Guide
VALUE
0,1 to 3,5 bar
(default 1.0 bar)
1-8 (Default 1)
1-4 Cycles (Default 1)
1:00 -12:59 HH.MM am/pm
(Default 9:00)
1:00 -12:59 HH.MM am/pm
(Default 21:00)
1:00 -12:59 HH.MM am/pm
(Default 21:10)
1:00 -12:59 HH.MM am/pm
(Default 21:20)
1:00 -12:59 HH.MM am/pm
(Default 21:30)
1:00 -12:59 HH.MM am/pm
(Default 21:40)
1:00 -12:59 HH.MM am/pm
(Default 21:50)
1:00 -12:59 HH.MM am/pm
(Default 22:00)
Turnovers
"
×
"
Cycle
Cycle
1
+
2
+
3
+
DESCRIPTION
The differential pressure from the 0-pressure to 100%
filter status.
The number of times per day the volume of water
setup in "Pool Volume" will be moved.
The number of cycles (start and stop) the IntelliFlo
must do per day.
Start time for cycle 1 (if start and stop is the same
time the IntelliFlo will run 24*7).
Stop time for cycle 1 (if start and stop is the same
time the IntelliFlo will run 24*7).
Start time for cycle 2. If "Cycles per day" is below 2,
"Disabled" will be displayed.
Stop time for cycle 2. If "Cycles per day" is below 2,
"Disabled" will be displayed.
Start time for cycle 3. If "Cycles per day" is below 3,
"Disabled" will be displayed.
Stop time for cycle 3. If "Cycles per day" is below 3,
"Disabled" will be displayed.
Start time for cycle 4. If "Cycles per day" is below 4,
"Disabled" will be displayed.
Stop time for cycle 4. If "Cycles per day" is below 4,
"Disabled" will be displayed.
p r
day
"
Cycle
4

Publicidad

Tabla de contenido
loading

Tabla de contenido