1777_20.960.07_Tauch_GB
Problem
Pump is running,
but does not deliver.
Pump doesn't start or
suddenly stops during
operation.
Pump runs, but output
suddenly decreases.
Attention!
If you have any problems with your Pump, please contact our Service.
8. Technical Data
Mains voltage/mains frequency
Rated Power
Connection cable
Max. delivery capacity
Max. pressure/head
Max. submersion depth
Min. depth of water for
switching on
Min./max. depth for
switching off
Residual depth of water
Dirty water with
max. particle diameter
Pump connection
Minimum water level at start-up
Weight
Max. water temperature
Cut-in/Cut-out height:
27.07.2011
15:50 Uhr
Probable cause
Feed impeller clogged.
When starting the pump,
water height falls below the
minimum water level.
Thermal overload switch has
switched the pump off due
to overheating.
No power.
Dirt particles are jammed
in the suction base.
Suction base is clogged.
Work on electrical parts must only be carried out by
GARDENA Service or an authorised GARDENA repairer.
Type 6000 (Art. No.1777)
220 – 240 V AC/50 Hz
220 W
10 m; H05-RN-F
6000 l/h
0.5 bar/5 m
7 m
Ca. 330 mm
Ca. 50 mm/95 mm
Empties down to approx. 5 mm
Ø 5 mm
38 mm (1
Option GARDENA plug-in connection water hose system for
connecting 13 mm (1/2")/15 mm (5/8")/19 mm (3/4") hoses.
50 mm
Ca. 3.1 kg
35 °C
The cut-in and cut-out height varies. The residual water height is
only reached during manual operation (see 4. Operation).
Seite 15
Remedy
➔ Disconnect plug and clean
feed impeller (see 6. Cleaning).
➔ Submerge pump deeper
into water.
➔ Disconnect plug and clean
feed impeller
(see 6. Cleaning).
Observe maximum water temper-
ature of 35 °C.
➔ Check fuse and electrical
plug and socket connections.
➔ Disconnect plug and clean
suction base
(see 6. Cleaning).
➔ Disconnect plug and clean
suction base
(see 6. Cleaning).
Type 6000 (Art. No. 1790)
220 – 240 V AC/50 Hz
220 W
10 m; H05-RN-F
6000 l/h
0.5 bar/5 m
7 m
Ca. 350 mm
Ca. 65 mm/120 mm
25 mm
Ø 25 mm
1
/
")-/25 mm (1")-stepped connection.
2
75 mm
Ca. 3.2 kg
35 °C
15