Stiebel Eltron ACCELERA 300 Manual De Operación E Instalación página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
INSTALLATION
» Remove the packaging straps.
» Push the packaging foil far enough upwards that the pallet is
freely accessible.
» Remove the water heater carefully with the polystyrene
packaging from the pallet.
DANGER Injury from tipping over
The water heater has a high centre of gravity and a
low overturning moment. Ensure that the water heater
does not overturn when you remove it from its pallet.
» Slide the packaging foil far enough upwards to be able to
remove the first polystyrene
polystyrene
profiles on the sides are used as installation
®
aids in the following steps.
» Separate the lower packaging section at the dividing line.
For this, make an incision of approx. 30 mm (1.25") into both
sides of the dividing line.
WWW.STIEBEL-ELTRON-USA.COM
®
profiles from the sides. These
®
» Slightly tilt the water heater.
DANGER Injury from overturning
Secure the water heater against overturning by
getting a second person to support the water heater.
» Push a wooden support underneath the lower part of the
packaging.
» Break out the free semi-shell of the lower section of the
packaging.
» Keep the water heaters slightly tilted.
» Wind out the free leveling foot, but not by more than 30 mm
(1.25").
» Turn the locking nut on the thread of the leveling foot
towards the bottom cover. When the locking nut is tight
against the bottom cover, it stabilizes the leveling foot.
ACCELERA® 300 HEAT PUMP WATER HEATER |
17

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido