Sacrificial Anode Rod - Stiebel Eltron ACCELERA 300 Manual De Operación E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
INSTALLATION
16
15
14
Air flow
13
1
Capacitor
2
Cable entry into the water heater casing
3
Strain relief (cable clamp)
4
Mains terminal
5
Frost monitor
6
Heat pump control thermostat
7
Fan motor
8
Heat pump terminal
9
Thermostat, booster heater
» Pull the power cable through the cable entry into the water
heater interior.
» Route the power cable through the strain relief (cable
clamp).
» Connect the power cable to the mains terminal in accordance
with the wiring diagram (see chapter 16.2 "Wiring Diagram".
L1, L2 and ground).
WARNING Electric shock
Risk of injury through inadequate grounding.
» Ensure that the water heater is correctly grounded
in accordance with the requirements at the place of
installation.
The ground conductor of the power cable must be
connected to the terminal marked G or Earth.
11.10.1 High limit safety cut-out
At ambient temperatures below -10 °C (14 °F), for example during
shipping or in storage, the high limit safety cut-out may trip.
Press the reset button of the high limit safety cut-out to reset it.
To do this, first remove the water heater cover.
WWW.STIEBEL-ELTRON-USA.COM
1
2
11
12
10 High limit safety cut-out, booster heater,
manual reset (see 14.1.1)
11 Booster heater
12 Sacrificial anode
13 Safety pressure limiter, manual reset,
(see 14.1.2)
14 Condensate pan drain
15 Compressor
16 Compressor motor protection (Klixon),
delay auto reset (see 14.1.3)
1
1
Reset button for high limit safety cut-out
ACCELERA® 300 HEAT PUMP WATER HEATER |
3
CAUTION :
Risk of electric shock
Use copper conductors only
4
5
6
Air flow
7
8
9
10
21

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido