12. PLUMBING
Use 19mm (3/4") or 25mm (1") smooth bore reinforced pipework to connect to the pump.
Secure the pipework on inlet and outlet with worm drive hose clip (Fig 9)
13. INSTRUCTIONS FOR USE
Ensure that pump installation is thoroughly tested before first use.
NOTE - These are all automatic or semi-automatic applications; therefore ensure that the isolator
switch is turned on. Do not leave the craft unattended with the electrical system energized
except in a bilge application.
13.i GREY WASTE APPLICATION
GULPER® IC - WITH GREY WASTE WHALE® IC ACCESSORIES
Gulper® IC with Gulley IC - Switch on shower to run grey waste through Gulley IC and check pump
is operating (1 second start delay). NOTE The pump should stop 9 seconds after deactivation.
Gulper® IC with Two Way Manifold IC - Switch on shower and or sink to run grey waste through Two
Way Manifold IC and check pump is operating (1 second start delay). NOTE The pump should stop
9 seconds after deactivation.
Gulper® IC - used with non Whale® IC accessories - Activate the switch to check pump operation (1
second start delay). NOTE The pump should stop 9 seconds after deactivation.
14. MAINTENANCE
This Whale Gulper® IC is designed to only require minimal maintenance.
WARNING: Before servicing pump, turn off pump and drain water from system.
Annual Checks
•
Whale advise that the boat's plumbing system is checked annually for leaks and obstructions.
Also a pump electrics check is advisable.
•
Before inspecting or replacing the diaphragm, disconnect the electrical supply.
Optimal Performance
•
Ensure this product is clear of debris
IF THE PUMP IS NOT OPERATING AS EXPECTED:-
•
Loosen the hose clips to release the pump from plumbing.
•
Unscrew the Ezi-clamp clamping ring to release the pump head - see Fig 4
•
This will release the pump head, and allow easy access to the valves & diaphragm.
•
The diaphragm and valves should be checked for any excessive wear, damage or cracks,
and should be replaced if necessary (service kit AK2050 - replacement pump head).
Cleaning
Gulper® IC and accessories should be wiped clean regularly to maintain optimal performance and
ensure no clogging occurs. WARNING: Do not use abrasive cleaners.
Fig 9 Secure pipework