Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL5-S1 Serie Manual De Instrucciones

Sistema magnetostrictivo de medición de posición – forma constructiva de varilla
Ocultar thumbs Ver también para BTL5-S1 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL5-S1 _ _ (B)-M _ _ _ _ -K(8)-SR32/SR115/K_ _/F_ _
Magnetostrictive Linear Position Sensor – Rod Style
7

Technical data

7.1

Accuracy

The specifications are typical values for the BTL5-S... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
Position resolution
Repeat accuracy
Typical
Linearity deviation
at resolution ≤ 10 µm
at resolution > 10 µm
Temperature coefficient
1)
Max. detectable velocity
Hysteresis
Reproducibility
7.2

Ambient conditions

Ambient temperature
Ambient temperature for UL
(only BTL5-...-K...)
Storage temperature
Relative humidity
Rod pressure rating (when
installed in hydraulic cylinders)
at Ø 8 mm
at Ø 10.2 mm
Shock rating
Continuous shock
per IEC 60068-2-27
3),4)
Vibration
per EN 60068-2-6
3).4)
Degree of protection per
IEC 60529
Connector (when attached)
Cable
16
english
1; 2; 5; 10; 20; 40; 50;
100 μm
±10 µm
± 30 µm
± 2 LSB
≤ 35 ppm/K
10 m/s
<1 LSB
<2 LSB
2)
−40 °C...+85 °C
≤ 80° C
−40°C...+100 °C
< 90%, non-
condensing
≤ 250 bar
≤ 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10 ...2000 Hz
IP67
IP68
3)
7.3

Supply voltage (external)

Voltage, stabilized
:
5)
BTL5-_1_ _-...
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
7.4

Output

Signal cables
Interface
Clock frequency
Distance information
1) Nominal length 500 mm, magnet in the middle of the measuring range
2) For
: Use in enclosed spaces and up to a height of 2000 m above
sea level.
3) Individual specifications as per Balluff factory standard
4) Resonant frequencies excluded
5) For
: The BTL must be externally connected via a limited-energy
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or
UL 1585.
20...28 V DC
≤ 0.5 V
pp
< 90 mA
≤ 3 A
Installed
Transzorb diodes
500 V DC
–Data/+Data/–Clk/+Clk
RS 485/422
≤ 1000 kHz
24 or 25 bits serial

Publicidad

Tabla de contenido
loading