Adjusting Air Pressure; Loading Staples - Hitachi N 3804AB2 Instrucciones Y Manual De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English

ADJUSTING AIR PRESSURE

Adjust the air pressure at recommended operating pressure 70 – 120 psi (4.9 – 8.3 bar
2
5 – 8.5 kgf/cm
) according to the length of staples and the hardness of workpiece.
The correct air pressure is the lowest pressure which will do the job. Using the Stapler at a
higher than required air pressure unnecessarily over stresses the Stapler.

LOADING STAPLES

When loading staples into Stapler,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Stapler pointed downward.
(1) Pull the staple feeder backward, and
confirm that the lock button is securely
lodged in the lock button hole on the staple
feeder.
(2) Place the staple strip over the magazine.
Make sure that the staple strip slides freely
on the magazine.
16
WARNING
Do not exceed 120
psi (8.3 bar 8.5
kgf/cm
WARNING
2
).
Lock Button
Staple Feeder
Magazine
Staple

Publicidad

Tabla de contenido
loading

Tabla de contenido