ADJUSTING AIR PRESSURE

● Do not exceed 120 psi (8.3 bar 8.5 kgf/cm
Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
according to the length of staples and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Stapler at a higher than required air
pressure unnecessarily over stresses the Stapler.

LOADING STAPLES

● When loading staples into Stapler,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Stapler pointed downward.
(1) Pull the staple feeder backward, and confi rm that
the feeder stopper is securely lodged in the feeder
stopper hole on the staple feeder.
Staple feeder
(2) Place the staple strip over the magazine.
Make sure that the staple strip slides freely on the
magazine.
14
WARNING
WARNING
Feeder stopper
).
2
Staple
(3) Pull the staple feeder backward slightly, and press in
)
2
the feeder stopper. Push the staple feeder forward.
Gently set the staple feeder to the back of the loaded
staples.
The Stapler is now ready to operate.
CAUTION
If the staple feeder is released all of a sudden, it
can return abruptly, causing deformation and/or
scatter, eventually ending up in clogged staples.
Be absolutely sure to bring back the staple
feeder, avoiding any impact.

STAPLER OPERATION

Read section titled "SAFETY"(pages 4 – 8).
Magazine
Feeder stopper
1
2
3
Staple feeder
DANGER
● Operators and others in work
area
MUST
wear
glasses with side shields
which conforms to ANSI Z87.1
specifi cations.
Ordinary eyeglasses do not
provide adequate protection.
safety

Publicidad