Converting for Use with Natural Gas or
Propane Gas
This range arrives from factory adjusted for use with
natural gas. If using LP/propane gas, range must be
converted.
WARNING
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Converting Type 1 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap using a
wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Cap must show "LPG10" or "LP10".
A—Spring location
B—7/8 inch cap
C—Plastic insert
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap using a
wrench.
2. Reverse pressure regulator cap.
• Cap must show "LP".
7
/
inch
8
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Surface Burners for Use with
LP/Propane
1. Remove access covers located under burner control
panel.
• Each cover is attach with a screw.
2. While facing range front, turn orifice hoods
counterclockwise 1½ to 2 turns or until snug.
• Use ½ inch open end or 90° offset open end
wrench.
• Do not over tighten orifice hoods. If orifice hoods
are over tightened, gas supply can be cutoff or
orifice hoods can strip.
A—Access cover and screw
B—Orifice hood
C—Air shutter
3. Adjust air shutter using small screw driver.
• Slide air shutter until shutter is fully open.
4. Replace access cover and screw.