Problem
Operating
Green LED flashing
Red LED flashing
Green LED solid on
-
No soap comes out
-
-
-
-
-
-
Soap won't
stop running
-
-
Soap comes out
unexpectedlly
-
Amount of dispensed
-
soap is small
Type
Power supply
Sensor detection range
Ambient temperature
Humidity
Soap volume
Tank capacity

TROUBLESHOOTING

Cause
Soap is low
Battery is low
Pump is sticking
Soap viscosity is high
Sensor window is dirty
Sensor cable is disconnected
There is an obstruction in front of sensor window
Power supply (AC adapter or battery box) is disconnected
Tube is disconnected
AC adapter is not plugged in
Sensor window is dirty
There is an obstruction in front of sensor window
Sensor window is dirty
Soap will be automatic dispersed after 48 hours of non-usage to
prevent clogging.
Pump is not working correctly

SPECIFICATIONS

TES100AA
AC
AC 100~240V
For use with Listed Class 2 power
supply or limited power source
5-7/8"±5/8"(150mm±15mm)
32~104°F (1~40°C)
0.03-0.04 oz (0.8-1.2ml)
14
Fill tank with liquid soap.
Replace batteries.
Clean the pump unit.
Change to TOTO
approved liquid soap.
Clean sensor window.
Connect cable.
Remove the obstruction.
Connect cable.
Connect tube.
Plug in the AC adapter.
Clean sensor window.
Remove the obstruction.
Clean sensor window.
-
Clean the pump unit.
4×D 1.5V alkaline batteries
Max. 90% RH
50 oz (1500ml)
Solution
TES100DA