Technical specifications
Measuring
resistance
(Ω)
Note
Continuity mode
( )
Diode test (
)
50
(cont.)
(cont.)
On this position, users can measure a resistance value.
Rate
Accuracy
0 to 500 Ω
0.1% + 5D
0.1% + 3D
5 kΩ
0.1% + 3D
50 kΩ
0.1% + 3D
500 kΩ
5 MΩ ( ∗)
0.5% + 3D
50 MΩ ( ∗)
1% + 5D
∗)
with default-activated filter
(
Automatic or manual range selection.
Open circuit maximum voltage: 9 V.
A shielded cable is recommended for measurements exceeding 5 M
On this position, users can measure a resistance value until 500 Ω, with
continuous audible indication at 4 kHz.
Continiuty mode detection threshold 10 to 15 Ω (reply time ≈1ms).
Rate
Precision
Beeper
0.1% + 5D
Open circuit maximum voltage: 9 V.
• Indicating interface voltage in current direction from 0 to 4.5 V for only
one range
• Precision: 0.2 % ± 3 D
• Indicating overshoot in reverse direction
• Measurement current: about 1 mA - V ≤ 2 V
• Open circuit maximum voltage: 9 V
Measurement
Resolution
currrent
1 mA
100 mΩ
1 Ω
100 µA
10 Ω
10 µA
100 Ω
1 µA
100 nA
1 kΩ
50 nA
10 kΩ
Measurement
Resolution
current
about 1 mA
100 mΩ
50,000-count Benchtop Multimeter
Technical Specifications
Protection
600 Vrms
Ω
.
Protection
600 Vrms

Publicidad