Before installing the sensor, make sure that the filtering is stopped and that the valves are shut. It is
designed to be fitted to rigid PVC piping Ø50 mm, Ø63 mm or Ø1 ½''. Do not install on any other type of
piping.
it must either be installed between the filtering pump and the filter, or between the filter and any other
equipment,
drill the pipe using a Ø9 mm (Ø10 mm maximum) drill bit, then deburr the hole,
install the supplied O‐ring on the sensor body so that is is positioned in its groove.
fix the sensor using the supplied stainless steel tightening collar. Do not tighten excessively.
position its cable neatly and connect the end to terminals 5 and 6 of the green connector on the AquaLink TRi®
electronic board (see wiring diagram §2.3.1).
There is no connection polarity for the sensor connection. It can be shortened if necessary, but not
extended.
"O‐ring" seal
2.4.3 "Solar priority" sensor connection
The AquaLink TRi® can be fitted with an extra water temperature sensor to manage a solar heating priority if the
pool is fitted with one.
This extra sensor is not supplied (the required model is the same as the original water temperature
sensor), see §5.2.
The sensor must be in the immediate proximity of the solar heating system to be able to measure a coherent
temperature.
to install it, proceed in the same way as for the water temperature sensor (see §2.4.2).
position its cable neatly and connect the end to terminals 3 and 4 of the green connector on the AquaLink TRi®
electronic board (see wiring diagram §2.3.1).
2.5 Connection to a heating system
AquaLink TRi® is compatible with al types of pool heating: heat pump, heat exchanger and electric warmer.
Thanks to its built‐in water temperature sensor, it can manage set point temperatures and thereby only start the
heating when needed.
2.5.1 Heating system equipped with a « on/off » remote control connector
You can drive a heating system using AquaLink TRi® if it is fitted with a specific contact for a remote '"on‐off"
command.
Examples of compatible heating systems:
Zodiac® EdenPAC, Power First Premium, Power Force, etc... heat pumps.
Connect a 2 x 0.75 mm² electric wire (not supplied) of the appropriate length to terminals 1 and 2 on the green
connector of the AquaLink TRi® electronic board (see §2.3.1),
connect the appliance contact to the wire (follow the connection and activation procedure for a remote
"on/off" switch in the appliance installation manual),
set the heating system set point temperature to the maximum. The AquaLink TRi® will manage the set point
temperature using its own water temperature sensor.
2.5.2 Heating system not equipped with a « on/off » remote control connector
Examples of affected heating systems:
Zodiac® Power, Optipac, Powerpac, Power First, etc... heat pumps, and any other brands,
Zodiac® Red Line +, etc... electric heaters, and any other brands,
Zodiac® Heat Line, Uranus, etc... heat exchangers, and any other brands.
H0369400.B.EN – 2013/03
Sensor
Stainless steel
6