4. Operational safety
4.1 Heating cooldown timer
If "Pool Mode" and the heating are operating at the same time, and if "Pool Mode" is turned to "Off", the filtering
pump will continue to operate alone for 5 minutes. A warning message "Heater Cooldown" will displayed during
this time. A flashing "***" symbol will be displayed on the "Pool Mode" menu.
An emergency stop is always possible by pressing the
4.2 Heating start‐up timer
Heating can only start if at least one of the 2 set points is activated ("Temp.1" and/or "Temp.2") and the water
temperature is below the active set point.
However, the heating system will not start immediately after a set point has been activated: a delay of one
minute will be observed before the "Temp.1" or "Temp.2" set point switches from "Auto" to "On".
An additional start‐up timer applies when a heat pump is connected to the AquaLink TRi®. This timer varies
from 3 to 5 minutes depending on the models between the time the AquaLink TRi® sends the start‐up
command and the actual start‐up of the heat pump.
4.3 Heating regulation timer
To avoid repeated start/stops when the pool water temperature is very close to the set point, a 3 minute timer is
applied between each heating start‐up command.
It is therefore normal that the heating system can remain off for several minutes even if the pool water
temperature is 1°C below the active set point.
4.4 Filtering timer with JVA valves
"Pool Mode" stops when a JVA motorised valve is activated (as well as the "Pool cleaner" if applicable). The
procedure lasts about 35 seconds. The "Pool Mode" restarts as soon as this operation is complete.
4.5 Cleaner lock
The pressure pool cleaner (controlled by its booster pump, itself connected to the AquaLink TRi®) can only
operate if the "Pool Mode" is activated and operational for more than 3 minutes.
If the "Cleaner" is active when the "Pool Mode" is "Off", "Pool Mode" will start automatically and the "Cleaner"
will start after a 3 minute timer (a message will be displayed on the Aqualink TRi® screen and the flashing "***"
symbol will be displayed on the "Cleaner" menu line).