ENGLISH

Section 11. Glossaries

11.1
Glossary of Safety Delays and
Lockouts
Lockouts
Any device can be locked out. This will prevent the
locked out device from being turned on manually.
However, the device will turn on/off when it is being
controlled by a schedule.
Pool/Spa Switching Filter Pump Delay
The filter pump turns off while valves rotate between
pool and spa to prevent damage to the pool equipment.
The valves take 35 seconds to rotate between pool and
spa; the filter pump will activate as soon as the valves
have finished turning.
Heater Cool Down Delay
When the system is heating (water is circulating to
the spa) and the Spa button is pressed, the system will
remain in Spa Mode for five (5) minutes, and will
continue to circulate the water. This delay allows water
to cool the heater down by circulating water through
it, preventing equipment damage. The five (5) minute
delay starts counting down when the heater goes off.
If the heater has been off for five (5) minutes or more,
prior to turning off the Spa, there will not be a delay.
Heater Start-up
The heater will only come on if the water is circulating
(for example, the filter pump is on and has been
circulating for 15 seconds) to the corresponding body
of water (for example, spa for spa heater) and the actual
water temperature is below the temperature you set with
Temp Set in the Menu. If these conditions are not met,
the heater will be enabled (ready to go), but will not
fire.
Heater "Short Cycling" Prevention
When the heater is activated and the desired temperature
is reached, heater will turn off and remain off for three
(3) minutes, even if the temperature falls below the
desired temperature. This feature prevents heater short
cycling (in other words, the heater turning off and on in
rapid succession).
AquaLink
Z4 | Installation Manual
®
Cleaner Lockout
The pool cleaner will only activate if the system is in
pool mode and water is circulating. The pool cleaner
requires that water is circulating to the pool in order
for it to operate. Return to pool mode to activate the
cleaner.
Spillover Lockout
The spillover will only activate if the system is in pool
mode and water is circulating. The spillover requires
that water is circulating to the pool in order for it to
operate. Return to pool mode to activate the waterfall.
Also, if the pool cleaner is on, it will turn off during
spillover operation.
Spillover
The spillover is disabled while the spa is on. A message
is displayed when spillover is turned on while in spa
mode (water is circulating to spa). The spillover requires
that water circulation is to pool in order to operate. The
spillover will activate when the system switches back to
pool mode.
Enabled
When activated allows the function to work.
Disabled
When activated does not allow the function to work.